All Products
Search
Document Center

Realtime Compute for Apache Flink:Manage variables

最終更新日:Oct 21, 2024

You can use variables to prevent security risks caused by information such as AccessKey pairs and passwords in plaintext. By using variables, you do not need to repeatedly write the same code or values. This simplifies configuration management. You can reference a variable in various scenarios, such as the SQL drafts and JAR or Python deployments, log output configuration, and UI-based parameter configuration. This topic describes how to create and use variables in different scenarios.

Background information

Each variable has a name and a value. The name reflects the meaning of the value and can be customized. The value is the actual data. Realtime Compute for Apache Flink supports deployment variables and namespace variables. The following section describes the differences between them:

  • Deployment variables: These variables can be used only in a single deployment. For example, they can be used in an SQL draft for extract, transform, load (ETL) or as the input parameters in the Main function of a JAR or Python deployment, in the format of ${Variable name}. For more information about how to use deployment variables, see the Deployment variables section in this topic.

  • Namespace variables: These variables can be used in a namespace. For example, they can be used for data development, such as data ingestion, ETL, and script-based query. They can also be used as the input parameters in the Main function of a JAR or Python deployment, in log configuration, and in UI-based parameter configuration, such as the parameters of a catalog. Namespace variables are in the format of ${secret_values.Variable name}. For more information about how to create and use namespace variables, see the Namespace variables section in this topic.

Usage notes

  • You cannot configure multiple values for a variable name.

  • Do not use a keyword as the variable name.

  • In SQL drafts, you can reference a variable only when you create a temporary table by using the CREATE TEMPORARY TABLE statement. If you reference a variable when you create a persistent table by using the CREATE TABLE statement, the table that you create cannot be used.

Deployment variables

Note

Deployment variable names must be unique within a single deployment.

Reference a variable in an SQL draft

You can use variables when you develop an SQL draft. For example, you can use variables as the input parameters of a custom function. You can also modify the variable values when the deployment is started.

  1. In the left-side navigation pane of the Realtime Compute for Apache Flink console, choose Development > ETL.

  2. In the SQL editor of the draft that you want to develop, create variables in the ${Variable name} format. The following sample code provides an example.

    • If you reference a variable in the WITH clause, you must enclose the variable with a pair of single quotation marks ('), in the '${Variable name}' format.

    • If you reference a variable as a table name or field name in an SQL statement, you must enclose the variable with a pair of grave accents (`), in the `${Variable name}` format.

    create temporary table `${source_name}`(
        id varchar,
        name varchar
    ) with (
        'connector' = 'datagen'
    );
    
    
    create temporary table blackhole(
        id varchar,
        `${test_name}` varchar
    ) with (
        'connector' = '${blackhole}'
    );
    
    insert into blackhole select * from `${source_name}`;
  3. Realtime Compute for Apache Flink automatically identifies variables in the required format in the draft. You need to use one of the following methods to configure the variable values:

    • Method 1: Enter a variable value in the Variables panel of the SQL editor.

      image

    • Method 2: Click the Configurations tab on the right side of the SQL editor. In the Configurations panel, enter a variable value in the Variables section.

      image

  4. After the draft is deployed, view the variable that is referenced in the deployment on the Configuration tab of the Deployments page.

    image

  5. On the Deployments page, find the deployment that you want to start and click Start in the Actions column. You can change the variable value in the Start Job panel.

    Important

    The new variable values take effect only for the deployment to be started. The variable values in the statement of the SQL draft remain unchanged.

    image

Reference a variable in a JAR or Python deployment

You can use variables as the input parameters in the Main function of a JAR or Python deployment.

  1. In the development console of Realtime Compute for Apache Flink, choose O&M > Deployments. On the Deployments page, click Create Deployment.

  2. Enter a variable name in the Entry Point Main Arguments field. Then, enter the variable value in the Variables section below the field.

    image

    For more information about other deployment parameters, see Create a deployment.

  3. Click Deploy.

  4. On the Deployments page, find the deployment that you want to start and click Start in the Actions column. You can change the variable value in the Start Job panel.

    image

Namespace variables

Create a variable

Note

Only members with the editor or higher permissions, or members with the variable creation permission can create variables.

  1. Log on to the Realtime Compute for Apache Flink console. Find the workspace that you want to manage and click Console in the Actions column.

  2. In the left-side navigation pane, choose Security > Variables. On the Variables page, click Add Variable.

    Parameter

    Description

    Variable Name

    Variable names must be unique in the same namespace and cannot be modified after the variables are created.

    Variable Value

    Variable values are case-sensitive. Pay attention to the case when you enter letters in a variable value. You can change the value of a variable after it is created. For more information, see the Edit or delete a variable section in this topic.

    Type

    You cannot modify the type of a variable after it is created. Valid values:

    • Plaintext: You can directly view the variable value on the Variables page.

    • Ciphertext: You cannot view the variable value.

    image

  3. Click OK.

Reference a variable

After you create a variable, you can reference the variable in the ${secret_values.Variable name} format. The following section provides examples for referencing a variable in different scenarios.

Reference a variable in data development

You can reference namespace variables in the Development module of the Realtime Compute for Apache Flink console.

SQL draft for ETL

In the DDL statement of an SQL draft, you can reference a variable in the ${secret_values.Variable name} format. The following sample code provides an example.

  • If you reference a variable in the WITH clause, you must enclose the variable with a pair of single quotation marks ('), in the '${secret_values.Variable name}' format.

  • If you reference a variable as a table name or field name in an SQL statement, you must enclose the variable with a pair of grave accents (`), in the `${secret_values.Variable name}` format.

create temporary table `${secret_values.source_name}`(
    id varchar,
    name varchar
) with (
    'connector' = 'datagen'
);


create temporary table blackhole(
    id varchar,
    `${secret_values.test_name}` varchar
) with (
    'connector' = '${secret_values.blackhole}'
);

insert into blackhole select * from `${secret_values.source_name}`;

Data ingestion

source:
  type: mysql
  name: Mysql Source
  hostname: localhost
  port: 3306
  username: test
  password: ${secret_values.mysqlpw}
  tables: app_db.\.*
  server-id: 5400-5404

···

Data query

USE CATALOG paimon;

CREATE DATABASE IF NOT EXISTS `${secret_values.test_name}`;

CREATE TABLE paimon.`${secret_values.test_name}`.ods_user_log
(
    item_id  int NOT NULL,
    `${secret_values.user}` varchar(50) NOT NULL,
    action  varchar(20)  NOT NULL,
    vtime   timestamp,
    ds      varchar(10) NOT NULL
)
PARTITIONED BY (ds);

SELECT * from paimon.`${secret_values.test_name}`.ods_user_log LIMIT 10;

Reference a variable in a JAR or Python deployment

You can use variables as the input parameters in the Main function of a JAR or Python deployment.

  1. In the development console of Realtime Compute for Apache Flink, choose O&M > Deployments. On the Deployments page, click Create Deployment.

  2. Enter a variable name in the Entry Point Main Arguments field, as shown in the following figure.

    image

    For more information about other deployment parameters, see Create a deployment.

  3. Click Deploy.

Reference a variable in the Logging section

  1. Go to the Logging section.

  2. Reference a variable in the Logging section.

    In the following example, the variables named accessKeyId and accessKeySecret are used to export logs of deployments to Simple Log Service. For more information about the complete configuration, see Configure parameters to export logs of a deployment.

    <Appender name="SLS" type="SLS">
      <Layout pattern="%d{yyyy-MM-dd HH:mm:ss,SSS}{GMT+8} %-5p %-60c %x - %m%n" type="PatternLayout" charset="UTF-8"/>  
    
      <!-- The final effective log path is: ${baseUri}/logs/${namespace}/${deploymentId}/{jobId}/ -->
      <Property name="namespace">{{ namespace }}</Property> <!-- Do not modify this line -->
      <Property name="project">YOUR-SLS-PROJECT</Property>  
      <Property name="logStore">YOUR-SLS-LOGSTORE</Property> 
      <Property name="endpoint">YOUR-SLS-ENDPOINT</Property> 
      <Property name="accessKeyId">${secret_values.accessKeyId}</Property> 
      <Property name="accessKeySecret">${secret_values.accessKeySecret}</Property> 
      <Property name="topic">{{ namespace }}:{{ deploymentId }}:{{ jobId }}</Property>
      <Property name="deploymentName">{{ deploymentName }}</Property>
      <Property name="flushIntervalSeconds">10</Property>
      <Property name="flushIntervalEventCount">100</Property>
    </Appender>

Reference a variable in UI-based parameter configuration

When you create a catalog in the development console of Realtime Compute for Apache Flink, you can reference a variable in a configuration item.

  1. In the development console of Realtime Compute for Apache Flink, click Catalogs in the left-side navigation pane.

  2. Reference a variable in the Create Catalog dialog box. In this example, the variable named mysqlpassword is used for the password parameter when you create a MySQL catalog.

    image.png

Edit or delete a variable

Note

Exercise caution when you edit or delete variables. Accidental operations may lead to a draft deployment failure or the need to redeploy a draft. If you delete an existing variable, the deployments that are running remain unaffected.

  1. Log on to the Realtime Compute for Apache Flink console. Find the workspace that you want to manage and click Console in the Actions column.

  2. In the left-side navigation pane, choose Security > Variables. On the Variables page, find the variable that you want to edit or delete and click Edit or Delete in the Actions column.

    • Edit a variable

      You can change the value of a variable. Only members with the editor or higher permissions can edit variables.

    • Delete a variable

      Only members with the editor or higher permissions, or members with the variable deletion permission can delete variables.

References

  • For more information about how to develop an SQL draft, see Develop an SQL draft.

  • For more information about parameters of a JAR or Python deployment , see Create a deployment.

  • For more information about how to create and use a catalog, see Manage catalogs.

  • For more information about the connectors that are supported by Realtime Compute for Apache Flink, see Supported connectors.