Initiates a connection from the router interface of an initiator to the router interface of an acceptor.
Usage notes
After you call this operation, the router interface enters the Connecting state. When the connection is established, it enters the Active state.
When you call this operation, take note of the following rules:
- Only an initiator router interface in the Idle state can initiate a connection.
- You can create only one pair of connected router interfaces between two routers.
- You cannot initiate a connection if your Alibaba Cloud account has a router interface with overdue payments.
Debugging
Request parameters
Parameter | Type | Required | Example | Description |
---|---|---|---|---|
Action | String | Yes | ConnectRouterInterface |
The operation that you want to perform. Set the value to ConnectRouterInterface. |
RegionId | String | Yes | cn-hangzhou |
The ID of the region where the router interface is deployed. You can call the DescribeRegions operation to query the most recent region list. |
RouterInterfaceId | String | Yes | ri-2zeo3xzyf38r4urzd**** |
The ID of the initiator router interface. |
Response parameters
Parameter | Type | Example | Description |
---|---|---|---|
RequestId | String | DE77A7F3-3B74-41C0-A5BC-CAFD188C28B6 |
The ID of the request. |
Examples
Sample requests
http(s)://[Endpoint]/?Action=ConnectRouterInterface
&RegionId=cn-hangzhou
&RouterInterfaceId=ri-2zeo3xzyf38r4urzd****
&Common request parameters
Sample success responses
XML
format
HTTP/1.1 200 OK
Content-Type:application/xml
<ConnectRouterInterfaceResponse>
<RequestId>DE77A7F3-3B74-41C0-A5BC-CAFD188C28B6</RequestId>
</ConnectRouterInterfaceResponse>
JSON
format
HTTP/1.1 200 OK
Content-Type:application/json
{
"RequestId" : "DE77A7F3-3B74-41C0-A5BC-CAFD188C28B6"
}
Error codes
HttpCode | Error code | Error message | Description |
---|---|---|---|
400 | IncorrectRole.NotInitiatingSide | The specified RouterInterface is not InitiatingSide. | The error message returned because the specified router interface is not an initiator. Select an initiator router interface. |
400 | IncorrectOppositeInterfaceInfo | Cannot connect on the same router | The error message returned because you cannot connect a router to itself. |
400 | Forbidden.OnlyOneConnection | The Specified routers have a connection already | The error message returned because the router is already connected to a router interface. |
400 | Forbidden.OnlyOneConnection | Cannot connect concurrently between same routers | The error message returned because you cannot initiate a connection on the same router. |
400 | Forbidden.BillsOutstanding | You cannot use this action because you have bills outstanding. | The error message returned because you have uncompleted payments and cannot call this operation. |
404 | InvalidRouterInterfaceId.NotFound | The specified RouterInterfaceId does not exist in our record. | The error message returned because the specified router interface does not exist. Check whether the specified router interface is valid. |
404 | CROSS_BID.FORBIDDEN | Connect RouterInterface across bid is illegal | The error message returned because cross-BID connections are invalid. |