All Products
Search
Document Center

Smart Access Gateway:DeleteSagExpressConnectInterface

Last Updated:Mar 29, 2024

Deletes a subinterface from a leased line port.

Debugging

OpenAPI Explorer automatically calculates the signature value. For your convenience, we recommend that you call this operation in OpenAPI Explorer.

Authorization information

There is currently no authorization information disclosed in the API.

Request parameters

ParameterTypeRequiredDescriptionExample
RegionIdstringYes

The ID of the region where the Smart Access Gateway (SAG) instance is deployed.

You can call the DescribeRegions operation to query the most recent region list.

cn-shanghai
SmartAGIdstringYes

The ID of the SAG instance.

sag-whfn****
SmartAGSnstringYes

The serial number of the SAG device associated with the SAG instance.

sag32a30****
PortNamestringYes

The name of the leased line port.

5
VlanstringYes

The VLAN ID of the leased line port.

Valid values: 0 to 4094.

Note
  • If the VLAN ID is 0, the leased line port is a physical port and does not support VLAN interfaces.
  • If the VLAN ID is 1 to 4094, the leased line port supports VLAN interfaces based on the Layer-3 protocols.
10

Response parameters

ParameterTypeDescriptionExample
object
RequestIdstring

The ID of the request.

AFF7E5A6-6897-4FDC-A5A8-1978B5B3E545

Examples

Sample success responses

JSONformat

{
  "RequestId": "AFF7E5A6-6897-4FDC-A5A8-1978B5B3E545"
}

Error codes

HTTP status codeError codeError messageDescription
400SAG.InstanceNoFoundThe specified SAG instance does not exist.The specified SAG instance does not exist.
400SAG.SoftwareNotSupportThe specified SAG software edition instance does not support ACL.The specified SAG software edition instance does not support ACL.
400InstanceNotExitThe specified instance does not exist.The specified instance does not exist.
400ConfigUnsynchronizedThe network configuration is not synchronized.Network settings are not synchronized.
403SmartAccessGatewayNotOnlineThe specified smart access gateway is not online.The specified SAG device is disconnected. The operation cannot be processed.
403FeatureNotSupportThe current edition of the smart access gateway does not support this feature.The current version of Smart Access Gateway does not support this feature.
403FeatureNotSupportForActiveSmartAGThe current edition of the active smart access gateway does not support this feature.The current edition of the active SAG instance does not support this feature.
403FeatureNotSupportForStandBySmartAGThe current edition of the standby smart access gateway does not support this feature.The current version of Smart Access Gateway does not support this feature.
500SmartAccessGatewayInArrearsThe specified Smart Access Gateway has expired.The specified Smart Access Gateway has expired.
500SmartAccessGatewayNotActivatedThe specified Smart Access Gateway has not been activated.The specified SAG instance is inactive. You must activate the instance first.
500SmartAccessGatewayOfflineThe request cannot be completed. The Smart Access Gateway is offline.The SAG device is disconnected. The request cannot be processed.

For a list of error codes, visit the Service error codes.