All Products
Search
Document Center

Energy Expert:Appendix to Enumerated Values

Last Updated:May 17, 2024

This topic describes the enumerated values of the carbon footprint and carbon inventory on the Energy Expert.

Carbon Footprint Appendix

Environment impact category enumeration

Num

Type

Meaning

1

gwp

climate change

2

odp

ozone depletion

3

htc

human toxicity: carcinogenic

4

htnc

human toxicity: non-carcinogenic

5

pm

particulate matter formation

6

irp

ionising radiation: human health

7

pocp

photochemical ozone formation: human health

8

ap

acidification

9

ae

eutrophication: terrestrial

10

p

eutrophication: freshwater

11

n

eutrophication: marine

12

et

ecotoxicity: freshwater

13

sqi

land use

14

wu

water use

15

mr

material resources: metals/minerals

16

er

energy resources: non-renewable

17

gwpf

climate change: fossil

18

gwpb

climate change: biogenic

19

gwpl

climate change: land use

Inventory&Benchmark type enumeration

Key

Value

1

Raw material

2

Energy

3

Resource

5

Packaging material

6

Product of other process

7

Consumable

8

Carbon sequestration

9

Transportation

21

Waste Gas

22

Waste Water

23

Waste Solid

Certificate status enumeration

Key

Description

1

Model Created

2

Result Generated

3

Submit Pending

4

To Be Verified

5

Under Verification

6

Rejected

7

Certificated Successfully

Product category enumeration

Key

First category

Second category

76-77

Agriculture, forestry and fishery products

Products of agriculture, horticulture and market gardening

76-78

Agriculture, forestry and fishery products

Live animals and animal products (excluding meat)

76-79

Agriculture, forestry and fishery products

Forestry and logging products

76-80

Agriculture, forestry and fishery products

Fish and other fishing products

81-82

Ores and minerals; electricity, gas and water

Coal and peat

81-83

Ores and minerals; electricity, gas and water

Crude petroleum and natural gas

81-84

Ores and minerals; electricity, gas and water

Uranium and thorium ores and concentrates

81-85

Ores and minerals; electricity, gas and water

Metal ores

81-86

Ores and minerals; electricity, gas and water

Stone, sand and clay

81-87

Ores and minerals; electricity, gas and water

Other minerals

81-88

Ores and minerals; electricity, gas and water

Electricity, town gas, steam and hot water

81-89

Ores and minerals; electricity, gas and water

Natural water

90-91

Food products, beverages and tobacco; textiles, apparel and leather products

Meat, fish, fruits, vegetables, oils and fats

90-92

Food products, beverages and tobacco; textiles, apparel and leather products

Dairy products and egg products

90-93

Food products, beverages and tobacco; textiles, apparel and leather products

Grain mill products, starches and starch products; other food products

90-94

Food products, beverages and tobacco; textiles, apparel and leather products

Beverages

90-95

Food products, beverages and tobacco; textiles, apparel and leather products

Tobacco products

90-96

Food products, beverages and tobacco; textiles, apparel and leather products

Yarn and thread; woven and tufted textile fabrics

90-97

Food products, beverages and tobacco; textiles, apparel and leather products

Textile articles other than apparel

90-98

Food products, beverages and tobacco; textiles, apparel and leather products

Knitted or crocheted fabrics; wearing apparel

90-99

Food products, beverages and tobacco; textiles, apparel and leather products

Leather and leather products; footwear

100-101

Other transportable goods, except metal products, machinery and equipment

Products of wood, cork, straw and plaiting materials

100-102

Other transportable goods, except metal products, machinery and equipment

Pulp, paper and paper products; printed matter and related articles

100-103

Other transportable goods, except metal products, machinery and equipment

Coke oven products; refined petroleum products; nuclear fuel

100-104

Other transportable goods, except metal products, machinery and equipment

Basic chemicals

100-105

Other transportable goods, except metal products, machinery and equipment

Other chemical products; man-made fibres

100-106

Other transportable goods, except metal products, machinery and equipment

Rubber and plastics products

100-107

Other transportable goods, except metal products, machinery and equipment

Glass and glass products and other non-metallic products n.e.c.

100-108

Other transportable goods, except metal products, machinery and equipment

Furniture; other transportable goods n.e.c.

100-109

Other transportable goods, except metal products, machinery and equipment

Wastes or scraps

110-111

Metal products, machinery and equipment

Basic metals

110-112

Metal products, machinery and equipment

Fabricated metal products, except machinery and equipment

110-113

Metal products, machinery and equipment

General-purpose machinery

110-114

Metal products, machinery and equipment

Special-purpose machinery

110-115

Metal products, machinery and equipment

Office, accounting and computing machinery

110-116

Metal products, machinery and equipment

Electrical machinery and apparatus

110-117

Metal products, machinery and equipment

Radio, television and communication equipment and apparatus

110-118

Metal products, machinery and equipment

Medical appliances, precision and optical instruments, watches and clocks

110-119

Metal products, machinery and equipment

Transport equipment

120-121

Constructions and construction services

Constructions

120-122

Constructions and construction services

Construction services

123-124

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Wholesale trade services

123-125

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Retail trade services

123-126

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Accommodation, food and beverage services

123-127

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Passenger transport services

123-128

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Freight transport services

123-129

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Rental services of transport vehicles with operators

123-130

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Supporting transport services

123-131

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Postal and courier services

123-132

Distributive trade services; accommodation, food and beverage serving services; transport services; and electricity, gas and water distribution services

Electricity, gas and water distribution (on own account)

133-134

Financial and related services; real estate services; and rental and leasing services

Financial and related services

133-135

Financial and related services; real estate services; and rental and leasing services

Real estate services

133-136

Financial and related services; real estate services; and rental and leasing services

Leasing or rental services without operator

137-138

Business and production services

Digital products and services

137-139

Business and production services

Research and development services

137-140

Business and production services

Legal and accounting services

137-141

Business and production services

Professional, technical and business services (except research, development, legal and accounting services)

137-142

Business and production services

Telecommunications, broadcasting and information supply services

137-143

Business and production services

Support services

137-144

Business and production services

Support and operation services to agriculture, hunting, forestry, fishing, mining and utilities

137-145

Business and production services

Maintenance, repair and installation (except construction) services

137-146

Business and production services

Manufacturing services on physical inputs owned by others

137-147

Business and production services

Other manufacturing services; publishing, printing and reproduction services; materials recovery services

148-149

Community, social and personal services

Public administration and other services provided to the community as a whole; compulsory social security services

148-150

Community, social and personal services

Education services

148-151

Community, social and personal services

Human health and social care services

148-152

Community, social and personal services

Sewage and waste collection, treatment and disposal and other environmental protection services

148-153

Community, social and personal services

Services of membership organizations

148-154

Community, social and personal services

Recreational, cultural and sporting services

148-155

Community, social and personal services

Other services

148-156

Community, social and personal services

Domestic services

148-157

Community, social and personal services

Services provided by extraterritorial organizations and bodies

158-159

Battery

Cell

158-160

Battery

Module

158-161

Battery

Pack

158-162

Battery

Energy storage system

158-163

Battery

Others

Unit enumeration

Key

Value

1-13

Piece(s)

1-14

Item(s)

1-4

kg

1-5

t

1-15

MJ

1-25

kWh

1-12

m3

1-146

个(which is used only for Chinese user and maybe changed in the future)

1-147

件(which is used only for Chinese user and maybe changed in the future)

1-148

只(which is used only for Chinese user and maybe changed in the future)

1-253

Mpa

1-252

2-146

个(which is used only for Chinese user and maybe changed in the future)

2-147

件(which is used only for Chinese user and maybe changed in the future)

2-148

只(which is used only for Chinese user and maybe changed in the future)

2-149

套(which is used only for Chinese user and maybe changed in the future)

2-150

箱(which is used only for Chinese user and maybe changed in the future)

2-151

盒(which is used only for Chinese user and maybe changed in the future)

2-152

袋(which is used only for Chinese user and maybe changed in the future)

2-153

瓶(which is used only for Chinese user and maybe changed in the future)

2-154

双(which is used only for Chinese user and maybe changed in the future)

2-155

罐(which is used only for Chinese user and maybe changed in the future)

2-156

桶(which is used only for Chinese user and maybe changed in the future)

2-157

块(which is used only for Chinese user and maybe changed in the future)

2-158

条(which is used only for Chinese user and maybe changed in the future)

2-131

Dozen(s)

2-13

Piece(s)

2-14

Item(s)

2-132

unit

3-16

lb av

3-17

Mg

3-18

oz av

3-19

oz t

3-20

sh tn

3-21

long tn

3-22

ug

3-23

ng

3-24

pg

3-3

g

3-4

kg

3-5

t

3-2

mg

4-15

MJ

4-25

kWh

4-26

TOE

4-27

J

4-181

KJ

4-28

kcal

4-29

btu

4-30

MWh

4-31

TCE

4-32

GJ

5-8

mm

5-9

cm

5-10

m

5-33

km

5-34

ft

5-35

mi

5-36

in

5-37

u

5-38

nmi

5-39

yd

6-12

m3

6-7

l

6-40

gal(US dry)

6-41

gal(US liq)

6-42

cu ft

6-43

fl oz(Imp)

6-44

US fl oz

6-45

pt(Imp)

6-46

bsh(US)

6-47

bsh(Imp)

6-48

ul

6-6

ml

6-49

bbl

6-50

bl(US beer)

6-51

bl(US fl)

6-52

bl(Imp)

6-53

bl(US dry)

6-133

pt (US fl)

6-134

pt (US dry)

6-135

gal (US fl)

6-136

gal (Imp)

6-138

Nm3

6-142

*10000 m3

7-11

m2

7-54

km2

7-55

ha

7-56

ft2

7-57

mi2

7-58

ac

7-59

yd2

7-60

cm2

7-61

nmi2

7-137

are

8-62

t*km

8-63

kg*km

8-64

lb*mi

8-65

t*mi

8-66

t*nmi

8-67

lb*nmi

8-68

metric ton*km

9-69

mol

10-71

Bq

10-72

Ci

10-73

Rutherford

10-70

kBq

11-74

d

11-75

h

11-76

s

11-77

a

11-78

min

12-81

Items*nmi

12-79

Items*km

12-80

Items*mi

13-82

m3*km

13-83

m3*mi

13-84

l*km

13-85

m3*nmi

13-86

l*mi

13-87

l*nmi

14-88

Items*a

15-91

kg*d

15-92

t*d

15-89

kg*a

15-90

t*a

16-93

m3*a

16-94

l*a

17-95

m2*a

17-96

km2*a

17-97

ha*a

17-98

ft2*a

17-99

mi2*a

17-100

m2*d

18-101

m*a

18-102

km*a

18-103

m*year

19-144

CNY

19-104

EUR

19-105

USD

19-106

JPY

19-107

AUD

19-108

CAD

19-109

DKK

19-110

CZK

19-111

CHF

19-112

EEK

19-113

GBP

19-114

HUF

19-115

ISK

19-116

KRW

19-117

LTL

19-118

LVL

19-119

NOK

19-120

SEK

19-121

ZAR

19-145

CNY (10k)

20-122

Cases

20-191

Room per night

21-123

Seconds worked

21-124

Hours worked

21-125

Hours workded(60min/h)

21-126

Minutes worked

21-127

Person days(8h/d)

21-128

Person years(220d/a)

22-129

kg/a

23-130

Person*km

23-143

Vehicle*km

24-139

MB

24-140

GB

24-141

TB

25-159

kgCO₂e

25-160

gCO₂e

26-161

J/kg

26-162

KJ/kg

26-163

MJ/kg

26-164

GJ/kg

26-165

TJ/kg

26-166

J/t

26-167

KJ/t

26-168

MJ/t

26-169

GJ/t

26-170

TJ/t

26-171

J/Nm3

26-172

KJ/Nm3

26-173

MJ/Nm3

26-174

GJ/Nm3

26-175

TJ/Nm3

26-176

J/10000Nm3

26-177

KJ/10000Nm3

26-178

MJ/10000Nm3

26-179

GJ/10000Nm3

26-180

TJ/10000Nm3

27-182

mg/ml

27-183

mg/l

27-184

mg/m3

27-185

g/ml

27-186

g/l

27-187

g/m3

27-188

kg/ml

27-189

kg/l

27-190

kg/m3

50-250

%

50-251

tC/t

Carbon inventory appendix

Module type and module correspondence table

Module type (moduleType)

Module Type Name

Module code (moduleCode)

Module Name

1

Three Scopes

carbonInventory.check.scope_1_direct_ghg_emissions

Scope 1

carbonInventory.check.scope_2_purchased_energy_indirect_ghg_emissions

Scope 2

carbonInventory.check.scope_3_other_indirect_ghg_emissions

Scope 3

3

Six Categories

carbonInventory.check.s_ca_1_direct_ghg_emissions_and_removals

Category 1

carbonInventory.check.s_ca_2_indirect_ghg_emissions_from_imported_energy

Category 2

carbonInventory.check.s_ca_3_indirect_ghg_emissions_from_transportation

Category 3

carbonInventory.check.s_ca_4_indirect_ghg_emissions_from_pros_used_by_an_org

Category 4

carbonInventory.check.s_ca_5_indirect_ghg_emissions_associated_with_the_use_of_pros_from_the_org

Category 5

carbonInventory.check.s_ca_6_indirect_ghg_emissions_from_other_sources

Category 6

Energy saving and carbon reduction

Required: Data that must be uploaded to ensure the use of the basic functions Recommended: Data that some functions depend on, If it is missing, it will affect the use of some functions or the accuracy Optional: Reserved field, will be better displayed if provided Noted: All device identify fields are case sensitive.

Device type

Device Type

Identifier

Watt-hour meter

1

Steam meter

2

Water meter

3

Inverter

4

Water chilling unit

5

Cooling tower

6

Water pump

7

System operation status in summer

8

System operation status in winter

9

Air handing unit and make-up air unit

10

Instrument energy consumption

11

Indoor environment

12

Indoor pedestrian flow

13

Boiler

14

Real weather

15

Weather forecast

16

Building and floor data

17

Gas meter

18

Energy management device list

Each device is independent in Energy Management. Device field data can be uploaded according to user needs.

Watt-hour meter

Data sampling frequency: once every 5 minutes is recommended, at least once every 30 minutes.

field description

unit

identify

type

Level

remarks

electric current of A phase

A

Ia

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

electric current of B phase

A

Ib

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

electric current of C phase

A

Ic

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

voltage of A phase

V

Ua

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

voltage of B phase

V

Ub

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

voltaget of C phase

V

Uc

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

voltage of AB line

V

Uab

DOUBLE

Optional

voltage of BC line

V

Ubc

DOUBLE

Optional

voltage of CA line

V

Uca

DOUBLE

Optional

total active power

W

P

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

active power of A phase

W

Pa

DOUBLE

Recommend

Affect Historical Energy Consumption

active power of B phase

W

Pb

DOUBLE

Recommend

Affect Historical Energy Consumption

active power of C phase

W

Pc

DOUBLE

Recommend

Affect Historical Energy Consumption

total reactive power

Var

Q

DOUBLE

Recommend

Affect Device Status and Historical Energy Consumption

reactive power of A phase

Var

Qa

DOUBLE

Recommend

Affect Historical Energy Consumption

reactive power of B phase

Var

Qb

DOUBLE

Recommend

Affect Historical Energy Consumption

reactive power of C phase

Var

Qc

DOUBLE

Recommend

Affect Historical Energy Consumption

total apparent power

VA

S

DOUBLE

Recommend

Affect Historical Energy Consumption

apparent power of A phase

VA

Sa

DOUBLE

Recommend

Affect Historical Energy Consumption

apparent power of B phase

VA

Sb

DOUBLE

Recommend

Affect Historical Energy Consumption

apparent power of C phase

VA

Sc

DOUBLE

Recommend

Affect Historical Energy Consumption

total power factor

/

COSQ

DOUBLE

Recommend

Affect Device Status, Historical Energy Consumption and Energy Dashboard

power factor of A phase

/

COSa

DOUBLE

Optional

power factor of B phase

/

COSb

DOUBLE

Optional

power factor of C phase

/

COSc

DOUBLE

Optional

frequency

Hz

F

DOUBLE

Recommend

Affect Device Status

total positive active power

kW·h

Ep_imp

DOUBLE

Required

Affect watt-hour meter basic function

total negative active power

kW·h

Ep_exp

DOUBLE

Recommend

Affect Device Status

total positive reactive power

kvarh

Eq_imp

DOUBLE

Recommend

Affect Device Status

total negative reactive power

kvarh

Eq_exp

DOUBLE

Recommend

Affect Device Status

positive tip active electrical energy

kW·h

Ep_imp_1

DOUBLE

Recommend

Affect Device Status

positive peak active electrical energy

kW·h

Ep_imp_2

DOUBLE

Recommend

Affect Device Status

positive flat active electrical energy

kW·h

Ep_imp_3

DOUBLE

Recommend

Affect Device Status

positive valley active electrical energy

kW·h

Ep_imp_4

DOUBLE

Recommend

Affect Device Status

negative tip active electrical energy

kW·h

Ep_exp_1

DOUBLE

Optional

negative peak active electrical energy

kW·h

Ep_exp_2

DOUBLE

Optional

negative flat active electrical energy

kW·h

Ep_exp_3

DOUBLE

Optional

negative valley active electrical energy

kW·h

Ep_exp_4

DOUBLE

Optional

total harmonic of phase A current

0%

IaTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

total harmonic of phase B current

0%

IbTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

total harmonic of phase C current

0%

IcTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

total harmonics of phase A voltage

0%

UaTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

total harmonics of phase B voltage

0%

UbTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

total harmonics of phase C voltage

0%

UcTHD

DOUBLE

Recommend

Affect Historical Energy Consumption

demand amount of positive active power

/

Dp_imp

DOUBLE

Recommend

Affect Device Status and Energy Dashboard

demand amount of negative active power

/

Dp_exp

DOUBLE

Recommend

Affect Device Status

demand amount of positive reactive power

/

Dq_imp

DOUBLE

Optional

demand amount of negative reactive power

/

Dq_exp

DOUBLE

Optional

Maximum daily active power demand

KW

Dp_imp_day

DOUBLE

Optional

Maximum monthly active power demand

KW

Dp_imp_mon

DOUBLE

Optional

Maximum monthly active power demand of last month

KW

Dp_imon

DOUBLE

Optional

Voltage unbalance rate

%

VdisPer

DOUBLE

Recommend

Affect Device Status

Current unbalance rate

%

LdisPer

DOUBLE

Optional

Phase A temperature on the outgoing side of the loop

T_OUTa

DOUBLE

Optional

Phase B temperature on the outgoing side of the loop

T_OUTb

DOUBLE

Optional

Phase C temperature on the outgoing side of the loop

T_OUTc

DOUBLE

Optional

the zero line current

A

In

DOUBLE

Optional

meter communication status

/

M_STATUS

BOOL

Optional

Device communication status, 1: open, 0: closed

Steam meter

Data sampling frequency: once every 5 minutes is recommended, at least once every 30 minutes.

field description

unit

identify

type

level

remarks

mass cumulative flow

kg

quality_acc_flow

DOUBLE

Required

Affect steam meter basic function

heat cumulative flow

MJ

heat_acc_flow

DOUBLE

Recommend

Affect Historical Energy Consumption

mass instantaneous flow

kg/h

quality_inst_flow

DOUBLE

Recommend

Affect Historical Energy Consumption

heat instantaneous flow

MJ/h

heat_inst_flow

DOUBLE

Recommend

Affect Historical Energy Consumption

temperature

temp

DOUBLE

Recommend

Affect Historical Energy Consumption

pressure

MPa

pressure

DOUBLE

Recommend

Affect Historical Energy Consumption

vapor density

kg/m3

steam_density

DOUBLE

Recommend

Affect Historical Energy Consumption

Water meter

Data sampling frequency: once every 5 minutes is recommended, at least once every 30 minutes.

field description

unit

identify

type

level

remarks

cumulative flow

t

ljll

DOUBLE

Required

Affect water meter basic function

instantaneous flow

m³/h

ssll

DOUBLE

Recommend

Affect Historical Energy Consumption

temperature

temp

DOUBLE

Recommend

Affect Historical Energy Consumption

pressure

MPa

pressure

DOUBLE

Recommend

Affect Historical Energy Consumption

Inverter

Data sampling frequency: once every 5 minutes is recommended, at least once every 30 minutes.

field description

unit

identify

type

level

remarks

output current of A phase

A

Ia

DOUBLE

Recommend

Affect Device Status

output current of B phase

A

Ib

DOUBLE

Recommend

Affect Device Status

output current of C phase

A

Ic

DOUBLE

Recommend

Affect Device Status

output voltage of A phase

V

Ua

DOUBLE

Recommend

Affect Device Status

output voltage of B phase

V

Ub

DOUBLE

Recommend

Affect Device Status

output voltage of C phase

V

Uc

DOUBLE

Recommend

Affect Device Status

voltage of AB line

V

Uab

DOUBLE

Recommend

Affect Device Status

voltage of BC line

V

Ubc

DOUBLE

Recommend

Affect Device Status

voltage of CA line

V

Uca

DOUBLE

Recommend

Affect Device Status

active power

kW

P

DOUBLE

Recommend

Affect Device Status

reactive power

kVar

Q

DOUBLE

Recommend

Affect Device Status

cumulative power generation

kW·h

Etotal

DOUBLE

Required

Affect inverter basic function

annual power generation

kW·h

Eyear

DOUBLE

Recommend

Affect Device Status

monthly power generation

kW·h

Emonth

DOUBLE

Recommend

Affect Device Status

daily power generation

kW·h

Eday

DOUBLE

Recommend

Affect Device Status

power factor

/

COSQ

DOUBLE

Recommend

Affect Device Status

frequency

Hz

F

DOUBLE

Recommend

Affect Device Status

inverter efficiency

%

EFF

DOUBLE

Recommend

Affect Device Status

PV1 input current

A

IPV1

DOUBLE

Recommend

Affect Device Status

PV2 input current

A

IPV2

DOUBLE

Recommend

Affect Device Status

PV3 input current

A

IPV3

DOUBLE

Recommend

Affect Device Status

PV4 input current

A

IPV4

DOUBLE

Recommend

Affect Device Status

PV5 input current

A

IPV5

DOUBLE

Recommend

Affect Device Status

PV6 input current

A

IPV6

DOUBLE

Recommend

Affect Device Status

PV7 input current

A

IPV7

DOUBLE

Recommend

Affect Device Status

PV8 input current

A

IPV8

DOUBLE

Recommend

Affect Device Status

PV9 input current

A

IPV9

DOUBLE

Recommend

Affect Device Status

PV10 input current

A

IPV10

DOUBLE

Recommend

Affect Device Status

PV11 input current

A

IPV11

DOUBLE

Recommend

Affect Device Status

PV12 input current

A

IPV12

DOUBLE

Recommend

Affect Device Status

PV13 input current

A

IPV13

DOUBLE

Recommend

Affect Device Status

PV14 input current

A

IPV14

DOUBLE

Recommend

Affect Device Status

PV15 input current

A

IPV15

DOUBLE

Recommend

Affect Device Status

PV16 input current

A

IPV16

DOUBLE

Recommend

Affect Device Status

PV17 input current

A

IPV17

DOUBLE

Recommend

Affect Device Status

PV18 input current

A

IPV18

DOUBLE

Recommend

Affect Device Status

PV19 input current

A

IPV19

DOUBLE

Recommend

Affect Device Status

PV20 input current

A

IPV20

DOUBLE

Recommend

Affect Device Status

PV1 input voltage

V

UPV1

DOUBLE

Recommend

Affect Device Status

PV2 input voltage

V

UPV2

DOUBLE

Recommend

Affect Device Status

PV3 input voltage

V

UPV3

DOUBLE

Recommend

Affect Device Status

PV4 input voltage

V

UPV4

DOUBLE

Recommend

Affect Device Status

PV5 input voltage

V

UPV5

DOUBLE

Recommend

Affect Device Status

PV6 input voltage

V

UPV6

DOUBLE

Recommend

Affect Device Status

PV7 input voltage

V

UPV7

DOUBLE

Recommend

Affect Device Status

PV8 input voltage

V

UPV8

DOUBLE

Recommend

Affect Device Status

PV9 input voltage

V

UPV9

DOUBLE

Recommend

Affect Device Status

PV10 input voltage

V

UPV10

DOUBLE

Recommend

Affect Device Status

PV11 input voltage

V

UPV11

DOUBLE

Recommend

Affect Device Status

PV12 input voltage

V

UPV12

DOUBLE

Recommend

Affect Device Status

PV13 input voltage

V

UPV13

DOUBLE

Recommend

Affect Device Status

PV14 input voltage

V

UPV14

DOUBLE

Recommend

Affect Device Status

PV15 input voltage

V

UPV15

DOUBLE

Recommend

Affect Device Status

PV16 input voltage

V

UPV16

DOUBLE

Recommend

Affect Device Status

PV17 input voltage

V

UPV17

DOUBLE

Recommend

Affect Device Status

PV18 input voltage

V

UPV18

DOUBLE

Recommend

Affect Device Status

PV19 input voltage

V

UPV19

DOUBLE

Recommend

Affect Device Status

PV20 input voltage

V

UPV20

DOUBLE

Recommend

Affect Device Status

negative electrode to ground voltage

V

UnegGD

DOUBLE

Recommend

Affect Device Status

internal air temperature

Tinner

DOUBLE

Recommend

Affect Device Status

Gas meter

Data sampling frequency: once every 5 minutes is recommended, at least once every 30 minutes.

field description

unit

identify

type

level

remarks

cumulative flow under standard conditions

m3

acc_flow

DOUBLE

Required

Affect gas meter basic function

instantaneous flow under standard conditions

m3/h

standard_inst_flow

DOUBLE

Recommend

Affect Historical Energy Consumption

instantaneous flow under working condition

m3/h

working_inst_flow

DOUBLE

Recommend

Affect Historical Energy Consumption

temperature

temp

DOUBLE

Recommend

Affect Historical Energy Consumption

pressure

MPa

pressure

DOUBLE

Recommend

Affect Historical Energy Consumption

chilled return water temperature

°C

chw_return_temp

DOUBLE

Required

cooling water outlet temperature

°C

cw_supply_temp

DOUBLE

Optional

cooling return water temperature

°C

cw_return_temp

DOUBLE

Optional

evaporator saturation temperature

°C

eva_sat_temp

DOUBLE

Optional

condenser saturation temperature

°C

con_sat_temp

DOUBLE

Optional

evaporator pressure

MPa

eva_press

DOUBLE

Optional

condenser pressure

MPa

con_press

DOUBLE

Optional

fault alarm signal

/

fault_signal

INTEGER

Required

0: normal, 1: alarm

accumulated power consumption

kW·h

electricity

DOUBLE

Optional

Fields of HVAC management device

Water chilling unit

Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

status:

/

run_signal

INTEGER

Required

0: off, 1: on

load rate / current percentage

/

load_ratio

DOUBLE

Recommend

It is recommended to report at least one of load_ratio and active_power, and if both are uploaded, the load_ratio shall prevail

active power

KW

active_power

DOUBLE

Recommend

chilled water outlet temperature setting

°C

chwst_setting

DOUBLE

Required

chilled water outlet temperature

°C

chw_supply_temp

DOUBLE

Required

chilled return water temperature

°C

chw_return_temp

DOUBLE

Required

cooling water outlet temperature

°C

cw_supply_temp

DOUBLE

Optional

cooling return water temperature

°C

cw_return_temp

DOUBLE

Optional

evaporator saturation temperature

°C

eva_sat_temp

DOUBLE

Optional

condenser saturation temperature

°C

con_sat_temp

DOUBLE

Optional

evaporator pressure

MPa

eva_press

DOUBLE

Optional

condenser pressure

MPa

con_press

DOUBLE

Optional

fault alarm signal

/

fault_signal

INTEGER

Required

0: normal, 1: alarm

accumulated power consumption

kW·h

electricity

DOUBLE

Optional

Cooling tower

Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

status

/

run_signal

INTEGER

Required

0: off, 1: on

fan frequency

HZ

fan_freq

DOUBLE

Optional

fan gear

/

fan_level

INTEGER

Optional

fault alarm signal

/

fault_signal

INTEGER

Required

0: normal, 1: alarm

accumulated power consumption

kW·h

electricity

DOUBLE

Optional

active power

kW·h

active_power

DOUBLE

Optional

Water pump (all types)

Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

status

/

run_signal

INTEGER

Required

0: off, 1: on

frequency

Hz

freq

DOUBLE

Recommend

Only for variable frequency pumps; if not provided, direct frequency control and anomaly analysis are not supported

fault alarm signal

/

fault_signal

INTEGER

Required

0: normal, 1: alarm

accumulated power consumption

kW·h

electricity

DOUBLE

Optional

active power

kW

active_power

DOUBLE

Optional

Instrument energy consumption

For summer strategy, it is recommended to install one watt-hour meter for each chiller, one watt-hour meter for a set of primary chilled water pumps, one watt-hour meter for a set of secondary chilled water pumps (if any), one watt-hour meter for a set of cooling water pumps, one watt-hour meter for a set of cooling towers, one watt-hour meter for a set of AHU(if any) and one watt-hour meter for a set of MAU(if any); For winter strategy, it is recommended to install one watt-hour meter for a set of primary heating water pumps, one watt-hour meter for a set of secondary heating water pumps (if any), one watt-hour meter for a set of AHU and one watt-hour meter for a set of MAU;. Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

instrument energy consumption

kW·h

meter_energy

DOUBLE

Required

System operation status in summer

Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

air conditioning system id

/

system_id

STRING : VARCHAR(128)

Required

accumulated cooling capacity

KJ

total_cooling

DOUBLE

Recommend

'total_cooling' or 'chw_flow' must upload one. 'chw_flow' higher priority if both upload. If not provided, calculation accuracy will be reduced and COP or efficiency can not be provided.

chilled water header flow

m3/h

chw_flow

DOUBLE

Recommend

chilled water supply temperature

°C

chw_supply_temp

DOUBLE

Required

chilled water return temperature

°C

chw_return_temp

DOUBLE

Required

cooling water supply temperature

°C

cw_supply_temp

DOUBLE

Required

cooling water return temperature

°C

cw_return_temp

DOUBLE

Required

chilled water supply pressure

bar

chw_supply_press

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

chilled water return pressure

bar

chw_return_press

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

cooling water supply pressure

bar

cw_supply_press

DOUBLE

Optional

cooling water return pressure

bar

cw_return_press

DOUBLE

Optional

chilled water outlet temperature setting

°C

chwst_setting

DOUBLE

Optional

cooling water outlet temperature setting

°C

cwst_setting

DOUBLE

Recommend

Affect outlet temperature control of the cooling water.

chilled water pump frequency

Hz

chwp_freq

DOUBLE

Optional

chilled water control mode

/

chw_mode

INTEGER

Optional

1: differential pressure control; 0: frequency control

chilled water supply and return water pressure difference setting

bar

chw_press_setting

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

chilled water supply and return water temperature difference setting

°C

chw_temp_setting

DOUBLE

Recommend

If not provided, differential temperature control can not be provided.

System operation status in winter

Only required for heating system. Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

air conditioning system id

/

system_id

STRING : VARCHAR(128)

Required

accumulated heat supply

KJ

total_heating

DOUBLE

Recommend

'total_heating' or 'hw_flow' must upload one. 'hw_flow' higher priority if both upload. If not provided, HVAC load forecasting can not be provided and calculation accuracy will be reduced

hot water header flow

m3/h

hw_flow

DOUBLE

Recommend

hot water outlet temperature

°C

hw_supply_temp

DOUBLE

Required

hot water return temperature

°C

hw_return_temp

DOUBLE

Required

hot water outlet pressure

bar

hw_supply_press

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

hot water return pressure

bar

hw_return_press

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

hot water pump frequency

Hz

hwp_freq

DOUBLE

Optional

hot water control mode

/

hw_mede

INTEGER

Optional

1: differential pressure control; 0: frequency contro

setting of water pressure difference between hot water supply and return

bar

hw_press_setting

DOUBLE

Recommend

If not provided, differential pressure control can not be provided.

setting of water temperature difference between hot water supply and return

°C

hw_temp_setting

DOUBLE

Recommend

If not provided, differential temperature control can not be provided.

chilled water total flow

m3

chw_acc_flow

DOUBLE

Optional

instantaneous flow per minute

m3/min

inst_flow_m

DOUBLE

Optional

instantaneous flow per second

m3/s

inst_flow_s

DOUBLE

Optional

Air handling unit and make-up air unit

Only required for AHU and MAU control. Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

required

remark

fresh air temperature

°C

fresh_temp

DOUBLE

Optional

fresh air humidity

%

fresh_hum

DOUBLE

Optional

supply air temperature setting

°C

supply_temp_setting

DOUBLE

Recommend

If not provided, air temperature control can not be provided.

supply air temperature

°C

supply_temp

DOUBLE

Required

supply air humidity

%

supply_hum

DOUBLE

Required

return air temperature

°C

return_temp

DOUBLE

Required

return air humidity

%

return_hum

DOUBLE

Required

return air CO2 concentration

PPM

return_CO2

DOUBLE

Optional

fan frequency setting

Hz

fan_freq_setting

DOUBLE

Optional

frequency of supply fan

Hz

supply_fan_freq

DOUBLE

Recommend

Only for variable frequency fans. if not provided, direct frequency control and anomaly analysis are not supported

frequency setting of supply fan

Hz

sff_setting

DOUBLE

Recommend

Only for variable frequency fans. if not provided, direct frequency control and anomaly analysis are not supported

status of supply fan

/

supply_run_signal

INTEGER

Required

0: off; 1: on

exhaust fan frequency

Hz

exhaust_fan_freq

DOUBLE

Optional

exhaust fan frequency setting

Hz

eff_setting

DOUBLE

Optional

status of exhaust fan

/

exhaust_run_signal

INTEGER

Recommend

Required if any exhaust fans. 0: not started; 1: started

opening setting of fresh air valve

%

fresh_valve_setting

DOUBLE

Recommend

Required if fresh air valve is adjustable

opening feedback of fresh air valve

%

fresh_valve_feedback

DOUBLE

Recommend

Required if fresh air valve is adjustable

opening setting of cooling valve

%

cool_valve_setting

DOUBLE

Optional

feedback of opening of cooling valve

%

cool_valve_feedback

DOUBLE

Optional

operation mode

/

run_mode

INTEGER

Optional

0: fixed fan frequency, 1: CO2 concentration control

start stop status of heat recovery runner

/

heat_return_state

INTEGER

Optional

0: off, 1: on

return air valve setting

%

return_valve_setting

DOUBLE

Optional

return air valve feedback

%

return_valve_feedback

DOUBLE

Optional

static pressure setting

Pa

static_pressure_setting

DOUBLE

Recommend

Required if supply fans adopt static pressure control

static pressure value

Pa

static_pressure

DOUBLE

Recommend

Required if supply fans adopt static pressure control

Indoor environment

It is recommended to install at least one indoor environment sensor per 500 square meters; Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

air conditioning system id

/

system_id

STRING : VARCHAR(128)

Required

building id

/

building_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Be unique under the current air-conditioning system Example value: building_1

building name

/

building_name

STRING : VARCHAR(128)

Optional

Chinese or English

floor id

/

floor_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of building id. Be unique under the current air-conditioning system Example value: floor_1

floor name

/

floor_name

STRING : VARCHAR(128)

Optional

Chinese or English

campus id

/

campus_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. If there is no campus, leave it blank.

campus name

/

campus_name

STRING : VARCHAR(128)

Optional

Chinese or English. If there is no campus, leave it blank

fence id

/

fence_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of floor id. Custom logic cutting unit. Be unique under the current air-conditioning system. Example value: fence_1

indoor temperature

°C

temperature

DOUBLE

Required

indoor co2 concentration

PPM

co2

DOUBLE

Recommend

If not provided, the corresponding statistics are not supported

indoor humidity

%

humidity

DOUBLE

Optional

Indoor pedestrian flow

Optional, if not provided, HVAC load forecasting accuracy will be reduced and the corresponding statistics are not supported. Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

air conditioning system id

/

system_id

STRING : VARCHAR(128)

Required

building id

/

building_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Be unique under the current air-conditioning system Example value: building_1

building name

/

building_name

STRING : VARCHAR(128)

Optional

Chinese or English

floor id

/

floor_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of building id. Be unique under the current air-conditioning system Example value: floor_1

floor name

/

floor_name

STRING : VARCHAR(128)

Optional

Chinese or English

campus id

/

campus_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. If there is no campus, leave it blank.

campus name

/

campus_name

STRING : VARCHAR(128)

Optional

Chinese or English. If there is no campus, leave it blank

fence id

/

fence_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of floor id. Custom logic cutting unit. Be unique under the current air-conditioning system Example value: fence_1

number of indoor personnel

person

person_num

BIGINT

Required

Building and floor data

Data sampling frequency: Send the full amount of building and floor data for the first time to complete the initialization, and send the updated full amount of data every time when there is a modification.

field description

unit

identify

type

level

remark

air conditioning system id

/

system_id

STRING : VARCHAR(128)

Required

building id

/

building_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Be unique under the current air-conditioning system Example value: building_1

building name

/

building_name

STRING : VARCHAR(128)

Optional

Chinese or English

floor id

/

floor_id

STRING : VARCHAR(128)

Required

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of building id. Be unique under the current air-conditioning system Example value: floor_1

floor name

/

floor_name

STRING : VARCHAR(128)

Optional

Chinese or English

campus id

/

campus_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. If there is no campus, leave it blank.

campus name

/

campus_name

STRING : VARCHAR(128)

Optional

Chinese or English. If there is no campus, leave it blank

fence id

/

fence_id

STRING : VARCHAR(128)

Optional

A combination of English letters, numbers and underscores. The underscore is not allowed at the beginning or end. Sub-levels of floor id. Custom logic cutting unit. Be unique under the current air-conditioning system Example value: fence_1

number of indoor personnel

person

person_num

BIGINT

Required

Boiler

Only required for boiler heating system. Data sampling frequency: once every 5 minutes is recommended, at least once every 15 minutes.

field description

unit

identify

type

level

remark

status:

/

run_signal

INTEGER

Required

0: off, 1: on

water outlet temperature setting

°C

hwst_setting

DOUBLE

Required

hot water outlet temperature

°C

hw_supply_temp

DOUBLE

Required

hot water return temperature

°C

hw_return_temp

DOUBLE

Required

fire level

/

fire_level

INTEGER

Optional

0: fierce fire, 1: small fire

fault alarm signal

/

fault_signal

INTEGER

Required

0: normal, 1: alarm

gas flow

m3/h

gas_flow

DOUBLE

Required

Fields of weather

Real-time weather

Required, if not provided, HVAC Management is not available. Data sampling frequency: at least once every 30 minutes.

field description

unit

identify

type

required

remark

region code

/

ad_code

STRING : VARCHAR(128)

Required

longitude

/

longitude

STRING : VARCHAR(32)

Required

eg: 110.50

latitude

/

latitude

STRING VARCHAR(32)

Required

eg: 78.50

weather description

/

skycon

STRING VARCHAR(180)

Optional

value: see Weather description enumeration

temperature

°C

temperature

DOUBLE

Required

humidity

%

humidity

DOUBLE

Required

cloudrate

/

cloudrate

DOUBLE

Optional

rang: 0~1

short wave radiant flux

w/m2

dswrf

DOUBLE

Required

wind speed

m/s

wind_speed

DOUBLE

Optional

wind direction

°

wind_direction

DOUBLE

Optional

clockwise from north

pressure

Pa

pressure

DOUBLE

Optional

precipitation

mm/hour

precipitation

DOUBLE

Required

data upload time

/

record_time

STRING : VARCHAR(64)

Required

format: yyyy-mm-dd HH:mm:ss

Weather forecast

Required, if not provided, HVAC Management is not available. If not provided, EMS load forecasting function is not available. Provide hourly weather forecast for the next 48 hours or more, update 3 times a day is recommended, at least update 2 times a day.

field description

unit

identify

type

level

remark

region code

/

ad_code

STRING : VARCHAR(128)

Required

longitude

/

longitude

STRING : VARCHAR(32)

Required

eg: 110.50

latitude

/

latitude

STRING : VARCHAR(32)

Required

eg: 78.50

weather description

/

skycon

STRING : VARCHAR(180)

Optional

value: see Weather description enumeration

temperature

°C

temperature

DOUBLE

Required

humidity

%

humidity

DOUBLE

Required

cloudrate

/

cloudrate

DOUBLE

Optional

rang: 0~1

short wave radiant flux

w/m2

dswrf

DOUBLE

Required

wind speed

m/s

wind_speed

DOUBLE

Optional

wind direction

°

wind_direction

DOUBLE

Optional

pressure

Pa

pressure

DOUBLE

Optional

precipitation

mm/hour

precipitation

DOUBLE

Required

data upload time

/

record_time

STRING : VARCHAR(64)

Required

format: yyyy-mm-dd HH:mm:ss

forecast time

/

forecast_time

STRING : VARCHAR(64)

Required

format: yyyy-mm-dd HH:mm:ss

Weather description enumeration

weather description

value of skycon

remark

sunny (daytime)

CLEAR_DAY

cloudrate < 0.2

sunny (night)

CLEAR_NIGHT

cloudrate < 0.2

cloudy (daytime)

PARTLY_CLOUDY_DAY

0.8 >= cloudrate > 0.2

cloudy (night)

PARTLY_CLOUDY_NIGHT

0.8 >= cloudrate > 0.2

cloudy

CLOUDY

cloudrate > 0.8

light haze

LIGHT_HAZE

PM2.5 100~150

moderate smog

MODERATE_HAZE

PM2.5 150~200

heavy smog

HEAVY_HAZE

PM2.5 > 200

light rain

LIGHT_RAIN

0.08~3.44 mm/h

moderate rain

MODERATE_RAIN

3.44~11.33 mm/h

heavy rain

HEAVY_RAIN

11.33~51.30 mm/h

storm rain

STORM_RAIN

>= 51.30 mm/h

fog

FOG

Low visibility, high humidity, low wind speed, low temperature

light snow

LIGHT_SNOW

0.08~3.44 mm/h

moderate snow

MODERATE_SNOW

3.44~11.33 mm/h

heavy snow

HEAVY_SNOW

11.33~51.30 mm/h

storm snow

STORM_SNOW

>= 51.30 mm/h

dust

DUST

AQI > 150, PM10 > 150, humidity < 30%, wind speed < 6 m/s

sand

SAND

AQI > 150, PM10> 150, humidity < 30%, wind speed > 6 m/s

wind

WIND