Updates a recording configuration for an application. The recordings are stored in Object Storage Service (OSS).
Usage notes
Obtain the main streaming domain, and then call this operation to update a recording configuration.
QPS limit
You can call this operation up to 30 times per second per account. Requests that exceed this limit are dropped and you will experience service interruptions. We recommend that you take note of this limit when you call this operation. For more information, see QPS limits.
Debugging
Request parameters
Parameter | Type | Required | Example | Description |
Action | String | Yes | UpdateLiveAppRecordConfig | The operation that you want to perform. Set the value to UpdateLiveAppRecordConfig. |
DomainName | String | Yes | example.com | The main streaming domain. |
AppName | String | Yes | liveApp**** | The name of the application to which the live stream belongs. |
OssEndpoint | String | Yes | learn.developer.aliyundoc.com | The endpoint of the OSS bucket. To store live stream recordings in OSS, you need to create an OSS bucket in advance. For more information, see Configure OSS. |
StreamName | String | No | teststream | The name of the live stream. |
StartTime | String | No | 2018-04-10T09:57:21Z | The recording start time. Specify the time in the ISO 8601 standard in the yyyy-MM-ddTHH:mm:ssZ format. The time must be in UTC. Note The start time must be within seven days after the stream ingest starts. This parameter takes effect only for the live stream specified by the StreamName parameter. If the StreamName parameter is not specified, this parameter does not take effect. |
EndTime | String | No | 2018-04-16T09:57:21Z | The recording end time. Specify the time in the ISO 8601 standard in the yyyy-MM-ddTHH:mm:ssZ format. The time must be in UTC. Note The time range that is specified by the EndTime and StartTime parameters must be less than or equal to seven days. If the value exceeds seven days, ApsaraVideo Live considers seven days as the time range. This parameter takes effect only for the live stream specified by the StreamName parameter. If the StreamName parameter is not specified, this parameter does not take effect. |
OnDemand | Integer | No | 1 | Specifies whether to enable on-demand recording. Valid values:
Note If you set the OnDemand parameter to 1, you need to call the AddLiveRecordNotifyConfig operation to configure the OnDemandUrl parameter. Otherwise, ApsaraVideo Live does not perform on-demand recording. |
DelayTime | Integer | No | 180 | The interruption duration for merge. If the stream interruption duration exceeds the specified duration, a new recording is generated. The value of this parameter ranges from 15 to 21600 seconds. |
RecordFormat.N.CycleDuration | Integer | No | 1 | The recording cycle. Unit: seconds. If you do not specify this parameter, the default value 6 hours is used. Note
|
RecordFormat.N.Format | String | No | m3u8 | The recording format. Supported formats include M3U8, FLV, and MP4. Valid values: Important You need to specify at lease one of the RecordFormat and TranscodeRecordFormat parameters. If you set this parameter to m3u8 or cmaf, you must also specify the RecordFormat.N.SliceOssObjectPrefix and RecordFormat.N.SliceDuration parameters.
|
RecordFormat.N.SliceDuration | Integer | No | 30 | The duration of a single segment. Unit: seconds. Important This parameter takes effect only if you set the RecordFormat.N.Format parameter to m3u8 or cmaf. If you do not specify this parameter, the default value 30 seconds is used. Valid values: 5 to 30. |
TranscodeRecordFormat.N.CycleDuration | Integer | No | 21600 | The transcoded stream recording cycle. Unit: seconds. If you do not specify this parameter, the default value 6 hours is used. |
TranscodeRecordFormat.N.Format | String | No | m3u8 | The format of the transcoded stream recording. Supported formats include M3U8, FLV, and MP4. Valid values: Important If you set this parameter to m3u8 or cmaf, you must also specify the TranscodeRecordFormat.N.SliceOssObjectPrefix and TranscodeRecordFormat.N.SliceDuration parameters.
|
TranscodeRecordFormat.N.SliceDuration | Integer | No | 30 | The duration of a single segment in the transcoded stream recording. Unit: seconds. Important This parameter takes effect only if you set the TranscodeRecordFormat.N.Format parameter to m3u8 or cmaf. If you do not specify this parameter, the default value 30 seconds is used. Valid values: 5 to 30. |
TranscodeTemplates.N | String | No | sd |
|
Response parameters
Parameter | Type | Sample value | Description |
RequestId | String | 16A96B9A-F203-4EC5-8E43-CB92E68F4CD8 | The request ID. |
Examples
Sample requests
Sample success responses
JSON
format
HTTP/1.1 200 OK
Error codes
HTTP status codes | Error code | Error message | Description |
400 | InvalidOssBucket.Malformed | Specified parameter OssBucket is not valid. | The OSS bucket is malformed. Check whether the value of the OssBucket parameter is valid. |
400 | InvalidOssBucket.NotFound | The parameter OssBucket does not exist. | The OSS bucket is not found. Check whether the value of the OssBucket parameter is valid. |
400 | InvalidFormat.Malformed | Specified parameter Format is not valid. | The recording format is invalid. Check whether the value of the Format parameter is valid. |
400 | InvalidCycleDuration.Malformed | Specified CycleDuration Format is not valid. | The format of the recording cycle is invalid. Check whether the value of the CycleDuration parameter is valid. |
400 | MissingOssObjectPrefix | OssObjectPrefix is mandatory for this action. | The name of the recording is not specified. Check whether the value of the OssObjectPrefix parameter is valid. |
400 | InvalidOssObjectPrefix.Malformed | Specified parameter OssObjectPrefix is not valid. | The name of the recording is invalid. Check whether the value of the OssObjectPrefix parameter is valid. |
400 | InvalidSliceOssObjectPrefix.Malformed | Specified parameter SliceOssObjectPrefix is not valid. | The segment name is invalid. Check whether the value of the SliceOssObjectPrefix parameter is valid. |
400 | ConfigAlreadyExists | Config has already exist. | The configuration already exists. |
400 | InvalidStartTime.Malformed | Specified StartTime is malformed. | The format of the start time is invalid. Check whether the value of the StartTime parameter is valid. |
400 | InvalidEndTime.Malformed | Specified EndTime is malformed. | The format of the end time is invalid. Check whether the value of the EndTime parameter is valid. |
For a list of error codes, see Service error codes.